ICON
NAVO Directory
X Tip: What's a "Resource"?
Hosted By
STScI Home
Space Telescope
Science Institute

Resource Record Summary

Catalog Service:
The PPMXL Catalog

Short name: I/317
IVOA Identifier: ivo://CDS.VizieR/I/317Publisher: CDSivo://CDS[Pub. ID]
More Info: http://cdsarc.unistra.fr/cgi-bin/cat/I/317
VO Compliance: Level 2: This is a VO-compliant resource.
Status: active
Registered: 2010 Jul 11 09:10:47Z
Get XML

Description


USNO-B1.0 (Cat. I/284) and 2MASS (Cat. II/246) are the most widely used full-sky surveys. However, 2MASS has no proper motions at all, and USNO-B1.0 published only relative, not absolute (i.e. on ICRS) proper motions. We performed a new determination of mean positions and proper motions on the ICRS system by combining USNO-B1.0 and 2MASS astrometry. This catalog is called PPMXL, and it aims to be complete from the brightest stars down to about V=20 full-sky. PPMXL contains about 900 million objects, some 410 million with 2MASS photometry, and is the largest collection of ICRS proper motions at present. As representative for the ICRS we chose PPMX. The recently released UCAC3 (Cat. I/315) could not be used because we found plate-dependent distortions in its proper motion system north of -20{deg} declination. UCAC3 served as an intermediate system for {demta}<-20{deg}. The resulting typical individual mean errors of the proper motions range from 4mas/yr to more than 10mas/yr depending on observational history. The mean errors of positions at epoch 2000.0 are 80 to 120 mas, if 2MASS astrometry could be used, 150 to 300 mas else. We also give correction tables to convert USNO-B1.0 observations of e.g. minor planets to the ICRS system.

More About this Resource

About the Resource Providers

This section describes who is responsible for this resource

Publisher: CDSivo://CDS[Pub. ID]

Creators:
Roeeser S.Demleitner M.Schilbach E.

Contact Information:
X CDS support team
Email: cds-question at unistra.fr
Address: CDS
Observatoire de Strasbourg
11 rue de l'Universite
F-67000 Strasbourg
France

Status of This Resource

This section provides some status information: the resource version, availability, and relevant dates.

Version: n/a
Availability: This is an active resource.
  • This service provides only public data.
Relevant dates for this Resource:
  • Updated: 2018 Feb 02 14:43:06Z
  • Created: 2010 Jul 11 09:10:47Z

This resource was registered on: 2010 Jul 11 09:10:47Z
This resource description was last updated on: 2021 Oct 21 00:00:00Z

What This Resource is About

This section describes what the resource is, what it contains, and how it might be relevant.

Resource Class: CatalogService
This resource is a service that provides access to catalog data. You can extract data from the catalog by issuing a query, and the matching data is returned as a table.
Resource type keywords:
  • Catalog
Subject keywords:
  • Infrared photometry
  • Optical astronomy
  • Photographic photometry
  • Photometry
  • Astrometry
  • Proper motions
  • Surveys
Intended audience or use:
  • Research: This resource provides information appropriate for supporting scientific research.
More Info: http://cdsarc.unistra.fr/cgi-bin/cat/I/317 Literature Reference: 2010AJ....139.2440R

Related Resources:

Other Related Resources
TAP VizieR generic service(IsServedBy) ivo://CDS.VizieR/TAP [Res. ID]
Conesearch service(IsServedBy)
I/312 : PPMX Catalog of positions and proper motions (Roeser+ 2008) ivo://CDS.VizieR/I/312 [Res. ID]

Data Coverage Information

This section describes the data's coverage over the sky, frequency, and time.

Wavebands covered:

  • Optical
  • Infrared

Rights and Usage Information

This section describes the rights and usage information for this data.

Rights:

Available Service Interfaces

Custom Service

This is service that does not comply with any IVOA standard but instead provides access to special capabilities specific to this resource.

VO Compliance: Level 2: This is a VO-compliant resource.
Available endpoints for this service interface:
Custom Service

This is service that does not comply with any IVOA standard but instead provides access to special capabilities specific to this resource.

VO Compliance: Level 2: This is a VO-compliant resource.
Available endpoints for this service interface:
  • URL-based interface: http://vizier.unistra.fr/viz-bin/votable?-source=I/317
Table Access Protocol - Auxiliary ServiceXX

This is a standard IVOA service that takes as input an ADQL or PQL query and returns tabular data.

VO Compliance: Level 2: This is a VO-compliant resource.
Available endpoints for the standard interface:
  • http://tapvizier.u-strasbg.fr/TAPVizieR/tap
Simple Cone SearchXXSearch Me

This is a standard IVOA service that takes as input a position in the sky and a radius and returns catalog records with positions within that radius.

VO Compliance: Level 2: This is a VO-compliant resource.
Description:
Cone search capability for table I/317/sample (Example of formatted output)
Available endpoints for the standard interface:
  • http://vizier.unistra.fr/viz-bin/conesearch/I/317/sample?
Maximum search radius accepted: 180.0 degrees
Maximum number of matching records returned: 50000
This service supports the VERB input parameter:
Use VERB=1 to minimize the returned columns or VERB=3 to maximize.


Developed with the support of the National Science Foundation
under Cooperative Agreement AST0122449 with the Johns Hopkins University
The NAVO project is a member of the International Virtual Observatory Alliance

This NAVO Application is hosted by the Space Telescope Science Institute

Member
ivoa logo
Contact Us