Galileo EPD Calibrated Corrected Medium Res Data Collection
Short Name:
EPD-MED-RES
Date:
15 Dec 2022 19:27:13
Publisher:
Planetary Data System
Description:
These are reprocessed measurements by the Engergetic Particle
Detector (EPD) instrument onboard the Galileo spacecraft that orbited
Jupiter and measured intensities of ion and electron radiation in the
keV and MeV energy range. This set is version 31 of reprocessing and
version 1.0 of PDS delivery. Data in the medium resolution files
include measurements that are binned into channels responding to
certain energy and species ranges. The files are comma separated.
Invalid entries will have -1.000000E+38 as an entry. The first 4 lines
of each data text file provide information on the channels included
here: The first line of each file lists the names of the channels
included. The second line lists the center energies of these channels
in keV. The third line lists the channels again. The forth line lists
the mass of the measured particle in AMU. Zero mass refers to
electrons. The forth line in the data text file labels the columns
that follow in the file. The columns include times, radiation
measurements, spacecraft location, instrument look direction, and some
supplementary information. Radiation measurements are provided both as
best calibrated and cleaned intensities as well as raw, uncorrected
count rates. Columns with channel names followed by a "j" include
calibrated differential intensities of the given channel. If the value
is negative, it should be ignored and particularly not included in
averages. For the difference between -1.000000E+38 and all other
negative values, see the User Guide. Columns ending with "f" provide
differential intensities based on a combination of various channels.
Columns ending with "i" include calibrated integral intensities.
Columns with plain channel names describe the raw uncorrected count
rate. Columns ending with "bg" are raw count rates measured behind the
calibration shield. Each following line will provide the same data but
for different times. More information can be found in the User Guide.
This includes a limited set of channels with intermediate time and
pitch angle resolution. If columns with plain channel names have
-1.000000E+38 values, you might find valid values in the lower
resolution files.
Galileo EPD Calibrated Corrected Time-of-Flight Event Data Collection
Short Name:
EPD-TOF-EVE
Date:
15 Dec 2022 19:26:10
Publisher:
Planetary Data System
Description:
These are reprocessed measurements by the Engergetic Particle
Detector (EPD) instrument onboard the Galileo spacecraft that orbited
Jupiter and measured intensities of ion and electron radiation in the
keV and MeV energy range. This set is version 31 of reprocessing and
version 1.0 of PDS delivery. The TOFxE and DeltaExE files include
event data of ion measurements. Event data are different than the
channelized data in the high, medium, and low resolution files. Event
data record the full information of a measured particle. Every "event"
is the measurement of a time of flight (TOF) within the instrument and
energy deposited within a detector (TOFxE file), or two energy values
deposited within the two detector layers (DeltaExE file). The
deposited energy values are generally different from the energy the
particle has in the ambient space. Event data provides measured values
in the native resolution of the instrument. Because such high
resolution increases data volume, event data cannot be taken
continuously and downlinked all the time. Only the provided subset of
this data was kept. The files are comma separated. Invalid entries
will have values of -1.000000E+38. Times are provided in the format
Year.DOYHHMMSSM (first column) and fractional year (second column)
More information can be found in the User Guide. This file includes
measurements by the EPD/CMS/TOFxE instrument. For each counted event,
the energy deposited in the one solid state detector (Energy_keV
column) and the time of flight (TOF_ns) within the instrument are
recorded.
Galileo HIC Derived Ion Fluxes October 89 Solar Event Data Collection
Short Name:
GO-HIC-PJ-DER
Date:
15 Dec 2022 19:30:31
Publisher:
Planetary Data System
Description:
This collection contains values for the fluxes of heavy ions
associated with an energetic particle event of solar origin. The
values are derived from HIC data taken during the Interplanetary
Cruise to Jupiter.
Galileo Jupiter HIC Derived Energetic Ion Competition Data Collection
Short Name:
GO-HIC-J-DER
Date:
15 Dec 2022 19:25:36
Publisher:
Planetary Data System
Description:
This collection contains energetic (MeV) ion fluxes for a variety of
different Z values (carbon, oxygen, sulfur) derived from the Heavy Ion
Counter (HIC) instrument on the Galileo spacecraft. The data set
includes all recorded intervals at Jupiter.
Galileo Jupiter HIC High Resolution Raw Data Collection
Short Name:
GO-HIC-J-RAW
Date:
15 Dec 2022 19:24:14
Publisher:
Planetary Data System
Description:
This collection contains raw energetic (MeV) particle data measured
by the Heavy Ion Counter (HIC) instrument on the Galileo spacecraft.
This data set contains both real-time and recorded data for all
Jupiter orbits.
Galileo Jupiter HIC Survey Energetic Ion Count Rate Calibrated
Collection Data Collection
Short Name:
HIG-J-SRVY-CNT
Date:
15 Dec 2022 19:30:33
Publisher:
Planetary Data System
Description:
This collection contains energetic (MeV) ion count rates and events
measured by the Heavy Ion Counter (HIC) instrument on the Galileo
spacecraft. The data are derived from the raw real-time science (RTS)
data. There are two basic types of data files associated with the
full-rate reduced data: Detector Count Rates and Events (Pulse
Heights).
Galileo Jupiter Magnetometer Highres Callisto Data Collection
Short Name:
GO-MAG-JUP-CAL
Date:
15 Dec 2022 19:29:16
Publisher:
Planetary Data System
Description:
This data collection contains high time resolution magnetic field
vectors acquired by the Galileo magnetometer (MAG). It includes
satellite flyby Callisto data. These data were acquired in order to
characterize various portions of the Jovian magnetosphere at high time
resolution.
Galileo Jupiter Magnetometer Highres Europa Data Collection
Short Name:
GO-MAG-JUP-EUR
Date:
15 Dec 2022 19:29:32
Publisher:
Planetary Data System
Description:
This data collection contains high time resolution magnetic field
vectors acquired by the Galileo magnetometer (MAG). It includes
satellite flyby Europa data. These data were acquired in order to
characterize various portions of the Jovian magnetosphere at high time
resolution.
Galileo Jupiter Magnetometer Highres Ganymede Data Collection
Short Name:
GO-MAG-JUP-GAN
Date:
15 Dec 2022 19:25:05
Publisher:
Planetary Data System
Description:
This data collection contains high time resolution magnetic field
vectors acquired by the Galileo magnetometer (MAG). It includes
satellite flyby Ganymede data. These data were acquired in order to
characterize various portions of the Jovian magnetosphere at high time
resolution.
Galileo Jupiter Magnetometer Highres Io Data Collection
Short Name:
GO-MAG-JUP-IO
Date:
15 Dec 2022 19:28:54
Publisher:
Planetary Data System
Description:
This data collection contains high time resolution magnetic field
vectors acquired by the Galileo magnetometer (MAG). It includes
satellite flyby Io data. These data were acquired in order to
characterize various portions of the Jovian magnetosphere at high time
resolution.