- ID:
- ivo://CDS.VizieR/J/A+A/532/A36
- Title:
- Galilean satellites mutual events in 2009
- Short Name:
- J/A+A/532/A36
- Date:
- 21 Oct 2021
- Publisher:
- CDS
- Description:
- Photometry of mutual events between natural satellites has been verified to be a most effective and accurate ground-based method for obtaining accurate astrometric data through fitting the light curves observed during these events, and it will be valuable to develop the orbital models of the natural satellites. Mutual occultations of J2 Europa by J1 Io (Aug 28, 2009), J1 Io by J2 Europa (Nov 9 and Dec 11, 2009) and J1 Io by J3 Ganymede (Nov 28, 2009) were observed at Yunnan Observatory during the PHEMU09 international campaign. We will calculate the astrometric data of satellites by analyzing and fitting the light curves we got. The same model proposed by N.V. Emelianov (2003SoSyR..37..314E) was used to fit the light curves, with the Lommel-Seeliger scattering law taking into account. Dynamical quantities, such as the deviation of the observed relative satellite motion from the theoretical motion provided by the relevant ephemeris denoted as Dx and Dy, impact parameter and mid-time corresponding to the impact parameter, were obtained for each event respectively. These results have an accuracy of about several mas to 90mas for Dx and Dy and 0.31-2.97s for mid-time. The residuals in determination of longitude shifts (delta(l1) for J1 Io and delta(l2) for J2 Europa) explaining the shifts of the mid-times of the events, were also calculated in the section of discussion which is around 10km with the best ephemerides.
Number of results to display per page
Search Results
- ID:
- ivo://pds-ppi/galileo_epd_cal_corrected_cms_events_deltaexe/ppi/epn_core
- Title:
- Galileo EPD Calibrated Corrected Delta Event Data Collection
- Short Name:
- EPD-DELTA-EVE
- Date:
- 15 Dec 2022 19:26:15
- Publisher:
- Planetary Data System
- Description:
- These are reprocessed measurements by the Engergetic Particle Detector (EPD) instrument onboard the Galileo spacecraft that orbited Jupiter and measured intensities of ion and electron radiation in the keV and MeV energy range. This set is version 31 of reprocessing and version 1.0 of PDS delivery. The TOFxE and DeltaExE files include event data of ion measurements. Event data are different than the channelized data in the high, medium, and low resolution files. Event data record the full information of a measured particle. Every "event" is the measurement of a time of flight (TOF) within the instrument and energy deposited within a detector (TOFxE file), or two energy values deposited within the two detector layers (DeltaExE file). The deposited energy values are generally different from the energy the particle has in the ambient space. Event data provides measured values in the native resolution of the instrument. Because such high resolution increases data volume, event data cannot be taken continuously and downlinked all the time. Only the provided subset of this data was kept. The files are comma separated. Invalid entries will have values of -1.000000E+38. Times are provided in the format Year.DOYHHMMSSM (first column) and fractional year (second column) More information can be found in the User Guide. This file includes measurements by the EPD/CMS/DeltaExE instrument. For each counted event, the energy deposited in the two solid state detector layers (Ej_keV and Ek_keV columns) of the instrument are recorded.
- ID:
- ivo://pds-ppi/galileo_epd_cal_corrected_high_res/ppi/epn_core
- Title:
- Galileo EPD Calibrated Corrected High Res Data Collection
- Short Name:
- EPD-HIGH-RES
- Date:
- 15 Dec 2022 19:27:32
- Publisher:
- Planetary Data System
- Description:
- These are reprocessed measurements by the Engergetic Particle Detector (EPD) instrument onboard the Galileo spacecraft that orbited Jupiter and measured intensities of ion and electron radiation in the keV and MeV energy range. This set is version 31 of reprocessing and version 1.0 of PDS delivery. Data in the high resolution files include measurements that are binned into channels responding to certain energy and species ranges. The files are comma separated. Invalid entries will have -1.000000E+38 as an entry. The first 4 lines of each data text file provide information on the channels included here: The first line of each file lists the names of the channels included. The second line lists the center energies of these channels in keV. The third line lists the channels again. The forth line lists the mass of the measured particle in AMU. Zero mass refers to electrons. The forth line in the data text file labels the columns that follow in the file. The columns include times, radiation measurements, spacecraft location, instrument look direction, and some supplementary information. Radiation measurements are provided both as best calibrated and cleaned intensities as well as raw, uncorrected count rates. Columns with channel names followed by a "j" include calibrated differential intensities of the given channel. If the value is negative, it should be ignored and particularly not included in averages. For the difference between -1.000000E+38 and all other negative values, see the User Guide. Columns ending with "f" provide differential intensities based on a combination of various channels. Columns ending with "i" include calibrated integral intensities. Columns with plain channel names describe the raw uncorrected count rate. Columns ending with "bg" are raw count rates measured behind the calibration shield. Each following line will provide the same data but for different times. More information can be found in the User Guide. This file provides data with the highest available time and pitch angle resolution. Only a small set of channels is provided, limiting the energy resolution and coverage. If columns with plain channel names have -1.000000E+38 values, you might find valid values in the lower resolution files.
- ID:
- ivo://pds-ppi/galileo_epd_cal_corrected_low_res/ppi/epn_core
- Title:
- Galileo EPD Calibrated Corrected Low Res Data Collection
- Short Name:
- EPD-LOW-RES
- Date:
- 15 Dec 2022 19:28:50
- Publisher:
- Planetary Data System
- Description:
- These are reprocessed measurements by the Engergetic Particle Detector (EPD) instrument onboard the Galileo spacecraft that orbited Jupiter and measured intensities of ion and electron radiation in the keV and MeV energy range. This set is version 31 of reprocessing and version 1.0 of PDS delivery. Data in the low resolution files include measurements that are binned into channels responding to certain energy and species ranges. The files are comma separated. Invalid entries will have -1.000000E+38 as an entry. The first 4 lines of each data text file provide information on the channels included here: The first line of each file lists the names of the channels included. The second line lists the center energies of these channels in keV. The third line lists the channels again. The forth line lists the mass of the measured particle in AMU. Zero mass refers to electrons. The forth line in the data text file labels the columns that follow in the file. The columns include times, radiation measurements, spacecraft location, instrument look direction, and some supplementary information. Radiation measurements are provided both as best calibrated and cleaned intensities as well as raw, uncorrected count rates. Columns with channel names followed by a "j" include calibrated differential intensities of the given channel. If the value is negative, it should be ignored and particularly not included in averages. For the difference between -1.000000E+38 and all other negative values, see the User Guide. Columns ending with "f" provide differential intensities based on a combination of various channels. Columns ending with "i" include calibrated integral intensities. Columns with plain channel names describe the raw uncorrected count rate. Columns ending with "bg" are raw count rates measured behind the calibration shield. Each following line will provide the same data but for different times. More information can be found in the User Guide. This includes the full set of channels covering the full energy and species range of EPD. The time and pitch angle resolution is low. Higher resolution is available for some channels that can be found in the medium and high resolution files.the energy deposited in the one solid state detector (Energy_keV column) and the time of flight (TOF_ns) within the instrument are recorded.
- ID:
- ivo://pds-ppi/galileo_epd_cal_corrected_med_res/ppi/epn_core
- Title:
- Galileo EPD Calibrated Corrected Medium Res Data Collection
- Short Name:
- EPD-MED-RES
- Date:
- 15 Dec 2022 19:27:13
- Publisher:
- Planetary Data System
- Description:
- These are reprocessed measurements by the Engergetic Particle Detector (EPD) instrument onboard the Galileo spacecraft that orbited Jupiter and measured intensities of ion and electron radiation in the keV and MeV energy range. This set is version 31 of reprocessing and version 1.0 of PDS delivery. Data in the medium resolution files include measurements that are binned into channels responding to certain energy and species ranges. The files are comma separated. Invalid entries will have -1.000000E+38 as an entry. The first 4 lines of each data text file provide information on the channels included here: The first line of each file lists the names of the channels included. The second line lists the center energies of these channels in keV. The third line lists the channels again. The forth line lists the mass of the measured particle in AMU. Zero mass refers to electrons. The forth line in the data text file labels the columns that follow in the file. The columns include times, radiation measurements, spacecraft location, instrument look direction, and some supplementary information. Radiation measurements are provided both as best calibrated and cleaned intensities as well as raw, uncorrected count rates. Columns with channel names followed by a "j" include calibrated differential intensities of the given channel. If the value is negative, it should be ignored and particularly not included in averages. For the difference between -1.000000E+38 and all other negative values, see the User Guide. Columns ending with "f" provide differential intensities based on a combination of various channels. Columns ending with "i" include calibrated integral intensities. Columns with plain channel names describe the raw uncorrected count rate. Columns ending with "bg" are raw count rates measured behind the calibration shield. Each following line will provide the same data but for different times. More information can be found in the User Guide. This includes a limited set of channels with intermediate time and pitch angle resolution. If columns with plain channel names have -1.000000E+38 values, you might find valid values in the lower resolution files.
- ID:
- ivo://pds-ppi/galileo_epd_cal_corrected_cms_events_tof/ppi/epn_core
- Title:
- Galileo EPD Calibrated Corrected Time-of-Flight Event Data Collection
- Short Name:
- EPD-TOF-EVE
- Date:
- 15 Dec 2022 19:26:10
- Publisher:
- Planetary Data System
- Description:
- These are reprocessed measurements by the Engergetic Particle Detector (EPD) instrument onboard the Galileo spacecraft that orbited Jupiter and measured intensities of ion and electron radiation in the keV and MeV energy range. This set is version 31 of reprocessing and version 1.0 of PDS delivery. The TOFxE and DeltaExE files include event data of ion measurements. Event data are different than the channelized data in the high, medium, and low resolution files. Event data record the full information of a measured particle. Every "event" is the measurement of a time of flight (TOF) within the instrument and energy deposited within a detector (TOFxE file), or two energy values deposited within the two detector layers (DeltaExE file). The deposited energy values are generally different from the energy the particle has in the ambient space. Event data provides measured values in the native resolution of the instrument. Because such high resolution increases data volume, event data cannot be taken continuously and downlinked all the time. Only the provided subset of this data was kept. The files are comma separated. Invalid entries will have values of -1.000000E+38. Times are provided in the format Year.DOYHHMMSSM (first column) and fractional year (second column) More information can be found in the User Guide. This file includes measurements by the EPD/CMS/TOFxE instrument. For each counted event, the energy deposited in the one solid state detector (Energy_keV column) and the time of flight (TOF_ns) within the instrument are recorded.
- ID:
- ivo://pds-ppi/galileo_hic_prejup_derived/ppi/epn_core
- Title:
- Galileo HIC Derived Ion Fluxes October 89 Solar Event Data Collection
- Short Name:
- GO-HIC-PJ-DER
- Date:
- 15 Dec 2022 19:30:31
- Publisher:
- Planetary Data System
- Description:
- This collection contains values for the fluxes of heavy ions associated with an energetic particle event of solar origin. The values are derived from HIC data taken during the Interplanetary Cruise to Jupiter.
- ID:
- ivo://pds-ppi/galileo_hic_jup_derived/ppi/epn_core
- Title:
- Galileo Jupiter HIC Derived Energetic Ion Competition Data Collection
- Short Name:
- GO-HIC-J-DER
- Date:
- 15 Dec 2022 19:25:36
- Publisher:
- Planetary Data System
- Description:
- This collection contains energetic (MeV) ion fluxes for a variety of different Z values (carbon, oxygen, sulfur) derived from the Heavy Ion Counter (HIC) instrument on the Galileo spacecraft. The data set includes all recorded intervals at Jupiter.
- ID:
- ivo://pds-ppi/galileo_hic_jup_raw/ppi/epn_core
- Title:
- Galileo Jupiter HIC High Resolution Raw Data Collection
- Short Name:
- GO-HIC-J-RAW
- Date:
- 15 Dec 2022 19:24:14
- Publisher:
- Planetary Data System
- Description:
- This collection contains raw energetic (MeV) particle data measured by the Heavy Ion Counter (HIC) instrument on the Galileo spacecraft. This data set contains both real-time and recorded data for all Jupiter orbits.
- ID:
- ivo://pds-ppi/galileo_hic_jup_calibrated_survey_countrate/ppi/epn_core
- Title:
- Galileo Jupiter HIC Survey Energetic Ion Count Rate Calibrated Collection Data Collection
- Short Name:
- HIG-J-SRVY-CNT
- Date:
- 15 Dec 2022 19:30:33
- Publisher:
- Planetary Data System
- Description:
- This collection contains energetic (MeV) ion count rates and events measured by the Heavy Ion Counter (HIC) instrument on the Galileo spacecraft. The data are derived from the raw real-time science (RTS) data. There are two basic types of data files associated with the full-rate reduced data: Detector Count Rates and Events (Pulse Heights).